Flammable Safety Cabinet, Type 90 – CM-Line

Flammable Safety Cabinets, Type 90 by Labor Security Systems are TÜV Certified and purpose-built for the safe storage of flammable substances in South African laboratories. Available in both undercounter and tall models—such as AC 600 CM, AC 1200 CM, and drawer configurations—these cabinets comply with EN 14470-1 and SANS 54470-1 standards, offering 90 minutes of fire resistance.

Trust Apex Scientific for certified, high-quality laboratory safety solutions. Explore our full range and read our detailed Insights article on flammable safety cabinets in South Africa.

Flammable Safety Cabinets, Type 90 – CM Line Models for Reliable Laboratory Protection

Flammable Safety Storage Cabinets, Type 90 from Labor Security Systems offer certified and dependable storage for flammable liquids and solids in South African laboratories. These TÜV Certified cabinets comply with EN 14470-1, EN 16121, EN 16122, and SANS 54470-1. They are tested to resist fire for up to 90 minutes, ensuring the highest level of protection.

 

Certified Safety with Built-In Ventilation

To ensure safe operation, each cabinet features a dual-valve natural ventilation system. This enables air exchange at least 10 times the cabinet’s volume per hour, significantly reducing the risk of gas buildup. Additionally, you can connect the system to an air suction motor and add a charcoal filter to capture harmful vapors—protecting lab personnel from exposure.

 

Intelligent Fire Response Systems

In a fire event, the cabinet activates multiple automatic systems to isolate its contents and prevent flame spread. These include:

  • Doors that close automatically at 50 °C
  • Safety valves that seal at 70 ± 10 °C
  • Intumescent seals that expand to block heat and flames
  • The Ignis-Lock system that secures the doors during emergencies

 

Together, these features help safeguard both staff and stored materials.

 

Robust Construction and Practical Design

CM line cabinets use eco-friendly insulation and are built for durability and fire resistance. Tall models like the AC 600 CM and AC 1200 CM offer capacities between 100 and 160 litres. Undercounter versions—AC 600/50 CM, AC 900/50 CM, and AC 1200/50 CM—store between 15 and 30 litres. Drawer-equipped options (CM D and CM DD) improve organization and access.

Each unit comes with tray-style shelves and a spill collection basin for added safety. Moreover, the palletized base (with cover) simplifies delivery and installation, making these cabinets suitable for both new builds and retrofits.

View our range:

Flammable Safety Cabinet, Type 90 - AC 1200 CM
Cabinet for flammable substances width 1200 mm - AC 1200 CM
Flammable Safety Cabinet, Type 90 - AC 600 CM
Cabinet for flammable substances width 600 mm - AC 600 CM
Flammable Safety Cabinet, Underbench Type 90 - AC 1200/50 CM
Underbench cabinet for flammable substances width 1200 mm - AC 1200/50 CM
Flammable Safety Cabinet, Underbench Type 90 - AC 600/50 CM
Underbench cabinet for flammable substances width 600 mm - AC 600/50 CM
Cabinet for Flammables + Chemicals, Acids and Bases - KEMFIRE 1200/50 TYPE B
Underbench cabinet for flammable substances width 1200 mm - AC 1200/50 CM DD
Flammable Safety Cabinet, Underbench Type 90 - AC 1200/50 CM D
Underbench cabinet for flammable substances width 1200 mm - AC 1200/50 CM D
Flammable Safety Cabinet
Underbench cabinet for flammable substances width 900 mm - AC 900/50 CM D
Flammable Safety Cabinet, Underbench Type 90 – AC 900/50 CM
Underbench cabinet for flammable substances width 900 mm - AC 900/50 CM

Optimized for Laboratory Workflows

The CM line features internalized safety systems that preserve a clean, modern look. Whether you need a tall cabinet for bulk storage or an undercounter unit to fit beneath benches, these models are designed to integrate easily into your lab layout.

Accessories


Apex Scientific is your trusted supplier of certified laboratory safety equipment in South Africa. Explore our full product range and visit the Insights page to read our article, Flammable Safety Cabinets in South Africa: Regulations, Types, and Best Practices.

Tall Single Door and Double Door Units

ModelAC 600 CMAC 1200 CM
External dimensions (WxDxH)680x640x1950 mm1180x640x1950 mm
Internal dimensions (WxDxH)515x445x1685 mm1015x445x1685 mm
Weight350 Kg490 Kg
Total volume386LT761LT
Shelf capacity80 Kg80 Kg

 

Undercounter Units

ModelAC 600/50 CMAC 900/50 CMAC 900/50 CM DAC 1200/50 CMAC 1200/50 CM DAC 1200/50 CM DD
External dimensions (WxDxH)595x510x600 mm895x510x600 mm895x510x600 mm1100x510x600 mm1100x510x600 mm1100x510x600 mm
Internal dimensions (WxDxH)430x355x445 mm730x355x440 mm730x335x440 mm935x355x440 mm935x355x440 mm935x355x440 mm
Weight100 Kg145 Kg145 Kg170 Kg170 Kg170 Kg
Total volume75LT114LT114LT164LT164LT164LT
Shelf capacity80 Kg80 Kg80 Kg80 Kg80 Kg80 Kg
SKUDescription
FL012CMAC 1200 CM Flammable Safety Cabinet, Type 90, 761LT
FL006CMAC 600 CM Flammable Safety Cabinet, Type 90, 386LT
FL006/5 CMAC 600/50 CM Undercounter, Flammable Safety Cabinet, Type 90, 75LT
FL006/5CMDAC 600/50 CM D Undercounter, Flammable Safety Cabinet, Type 90, one drawer
FL009/5CMAC 900/50 CM Undercounter, Flammable Safety Cabinet, Type 90, 114LT
FL009/5CMDAC 900/50 CM D Undercounter, Flammable Safety Cabinet, Type 90, 114LT, one drawer
FL012/5 CMAC 1200/50 CM Undercounter, Flammable Safety Cabinet, Type 90, 164LT
FL012/5CMDAC 1200/50 CM D Undercounter, Flammable Safety Cabinet, Type 90, 164LT, one drawer
FL012/5CMDDAC 1200/50 CM DD Undercounter, Flammable Safety Cabinet, Type 90, 164LT, two drawers
CodeModelDescriptionDimensions WxDxH (mm)
F007SPARE FILTERSpare activated charcoal filter with CUNCTATOR®
KIT FINTERNAL FILTRATION KITNew internal filtration system with activated charcoal filter cell (F007) and CUNCTATOR® (for inflammable compartment)
CTT09CUNCTATOR® (**)Electronic system for replacement of filters – 9 months
TD005THERMIC DOOR’S LOCK WITH AUTOMATIC RELEASEThermic device for closing doors at 50°C1 FOR EACH DOOR
KIT03EXHAUST FUMES CONVEYORexhaust kit converter from the top just for underbench KEMFIRE
KIT03BEXHAUST FUMES CONVEYORexhaust kit converter from the top just for KEMFIRE 1100 A
KIT03BBEXHAUST FUMES CONVEYORexhaust kit converter from the top just for KEMFIRE 600 A
KIT05PASSING SYSTEMCertified passing system to pour waste liquids for underbench cabinets
KIT05.45BENT PASSING SYSTEMCertified passing system to pour waste liquids for underbench cabinets with 45 ° inclination

Insights Article: Flammable Safety Cabinets in South Africa: Regulations, Types, and Best Practices

Product Enquiry Handbook: Flammable Safety Storage Cabinets

Technical Specifications Sheet AC 600 CM

Technical Specifications Sheet AC 1200 CM

Technical Specifications Sheet Undercounter AC 600/50 CM

Technical Specifications Sheet Undercounter AC 900/50 CM

Technical Specifications Sheet Undercounter AC 900/50 CM D

Technical Specifications Sheet Undercounter AC 1200/50 CM

Technical Specifications Sheet Undercounter AC 1200/50 CM D

Technical Specifications Sheet Undercounter AC 1200/50 CM DD

Operating Manual